Click a drop down menu to view the latest Hebel information, technical manuals and brochures. For all technical specifications, please contact Darren on (07) to ensure you receive the most up-to-date and accurate information. The CSR Hebel Technical Manual has been prepared as a source of information to provide general guidance to consultants. The contents of the Technical Manual are provided with consideration to and in accordance with the relevant Australian standards, legislative requirements and building regulations. It is the responsibility of the user to. 4 From CSR Hebel Technical Manual – January 5. to the stud wall using top hat steel sections. The Hebel and Styrofoam panels were HEBEL 95 BY 45 MGP 10 @ 75 THICK HEBEL PANELS 50 THICK STYROFOAM REFLECTIVE INSULATION R BATT INSULATION BRICK VENEER 95 BY 45 MGP 10 @ FACE BRICK R BATT INSULATION 10 .
CSR Hebel Technical Manual • August 7 Wall Floor Panel Design Construction For other applications of CSR Hebel panels, the foundation or supporting structure should be designed by the project structural engineer to satisfy the performance requirements of masonry (such as, deflection limits and stiffness). Cracking in Masonry. 1 Technical Sheet Vertical Load Bearing Wall Phanel General Features Hebel AAC (Autoclaved Aerated ® Concrete) Wall Panels are lightweight, fire resistant, fast and easy to install. Hebel AAC Vertical ® Load-Bearing Wall Panel is a reinforced (Grade 70 steel) element spanning with full story height. The. CSR Hebel Technical Manual • January CSR Hebel floor panels are supplied with a recess and slot groove (DP). CSR Hebel vertical wall panels can be used with either a smooth (NIL) or rebate profile (such as tongue groove, TG or WA). CSR Hebel offers the following adhesive, mortar and render products to complement the CSR Hebel AAC.
1 Technical Sheet Hebel Wall Panel® General Features Lightweight, fire resistant*, water penetration resistant**, pest resistant, fast and easy to install, versatile and affordable. Hebel AAC Wall Panel is a steel reinforced element. Reinforcement is Grade 70 steel covered with an anti-corrosive coat. Manufactured according to. CSR Hebel Technical Manual • January 3 Energy Efficiency The quantity of energy, Q (kWh) flowing through the building component can be calculated by multiplying the considered surface area and the heat flow rate of the building component. Energy can be determined from the following expression: Q = U. A. Δt. T x where. Hebel AAC Technical Manual Xella Aircrete North America, Inc. Section www.doorway.ru Section 3: Material Properties Density Hebel AAC is a lightweight construction material with dry densities ranging from 25 pcf ( kg/m3) to 44 pcf ( kg/m3). Hebel AAC is manufactured in compliance with ASTM – Standard Specification for Precast.
0コメント