Gs-800 densitometer manual






















The Bio-Rad GS densitometer scans X-ray film, gels stained with Coomassie and other visible stains and blots. The instrument software can convert the images to TIFF files for presentation or further analysis. ImageQuant software from Amersham BioSciences, now GE HealthCare, can analyze images from the www.doorway.ruted Reading Time: 40 secs. The GS has a built-in calibrated optical density transmissive step tablet for unsurpassed accuracy. Each tablet contains a serial number for complete documentation to an external standard. The ability of the GS to calibrate to an external standard ensures accurate, reproducible results. 29 x 40 cm Format, Bit Precision. Image Lab Software for the GS Densitometer | 11 5. Result and Report Generation 1. Click Analysis Table in the menu bar to open a table of analysis results. Scroll through the data, or click in the gel image to view the data for a lane. 2. Click the Display Options icon to customize the data shown. 3.


1 in stock. Add to enquiry. Product Details. Technical Specifications. Description. The Bio-Rad GS is a Calibrated Imaging Densitometer that converts transparent and opaque electrophoretic samples into digital data. - GS Calibrated Imaging Densitometer - GS Calibrated Imaging Densitometer User Guide (as PDF) - UMAX PowerLook XL Operation Manual (as PDF) - 25/pin SCSI Cable - Power Cord. The GS Densitometer is in used but good cosmetic condition and % functional. The GS Calibrated Densitometer is a self-calibrating 21 CFR Part 11 gel imaging system for acquiring gel, blot, and film images. The GS Densitometer is an integral part of the Biologics Analysis Workflow, a complete, integrated solution. Read full description Ordering Information. Contact an Expert. Description.


Proteomics: BioRad GS Densiometer Basic Features Link to BioRad/UMAX GS Users Manual (pdf) The GS calibrated densitometer delivers automatic calibration for superior accuracy, resolution, and image quality. With a 30 x 40 cm (11 x 16") imaging platen, bit data collection, and resolution down to µm. BioRad GS™ calibrated densitometer Transmittance and Reflectance. Unlike laser densitometer systems the Bio-Rad GS calibrated densitometer has both transmittance and true reflectance capabilities that allow accurate scans of both transparent and opaque samples. The advantage of true reflectance scanning is accurate detection and analysis of molecules on the surface of membranes rather than molecules distributed throughout the membrane matrix. with the GS™ densitometer, Image Lab must calibrate and acquire the flat images. Note: It can take up to 30 minutes to acquire a flat image. When you first connect the instrument to the computer running Image Lab, the software prompts you to begin calibration. After the densitometer has been in use for some time, it might require.

0コメント

  • 1000 / 1000